Use of magnets in cardiology explored by robotics engineers

A multidisciplinary team of robotics and electronic systems engineers working with cardiologists and materials scientists has developed a medical robotic apparatus that uses an external magnetic field to precisely and remotely control guidewires through tiny and tortuous blood vessels.

The team, led by researchers at Daegu Gyeongbuk Institute of Science and Technology (DGIST), reported their results in the journal Advanced Healthcare Materials. The apparatus, following further tests and commercialisation, could minimise the exposure of physicians to X-ray radiation while looking for and treating narrowed or blocked blood vessels.

“Cardiovascular diseases are the leading cause of death worldwide, and it is very important to be able to diagnose and treat these diseases in the most minimally invasive way possible,” explained DGIST robotics engineer Hongsoo Choi. 

Currently, percutaneous coronary intervention (PCI) involves introducing a guidewire through the large femoral artery in the groin or the radial artery in the wrist and expertly manipulating it until it reaches the largest blood vessel in the body, the aorta. A contrast agent is then injected into the aorta, where it spreads into the coronary arteries that feed the heart. X-ray images are then taken to pinpoint any blockages present in these arteries. This intervention requires a huge amount of skill and can still lead to vessel perforation. It also involves unnecessary exposure of the physician to X-ray radiation, as the procedure is conducted at the patient’s bedside. 

In recent years, researchers have been investigating the use of robotic magnetic systems to improve the remote control of this sort of procedure. But the systems that have been developed are often bulky and do not respond quickly enough.

Now, Choi and his team have developed a system that involves remotely controlling a magnetically steerable microrobotic guidewire by applying a controllable external magnetic field. The field is generated by an ‘electromagnetic actuation system’ made of eight electromagnets arranged in a hemispherical configuration under a surgical bed. The patient is meant to be placed on the bed, with the guidewire inserted into an artery and guided remotely by changing the magnetic field. The guidewire is made of a biocompatible silicone tube that can move through blood vessels with very little surface friction. The tip of the microrobotic tube encapsulates a neodymium-iron-boron permanent magnet and hard-magnetic composites for magnetic steering. 

The researchers first tested the system using 2D- and 3D-printed blood vessel models. They then tested it in anaesthetised pigs, managing to remotely control the guidewires through small and tortuous arteries in the pelvis, kidneys and heart.

“Our proposed electromagnetically controllable microrobotic interventional system (ECMIS) could reduce radiation exposure of physicians by empowering them to conduct the procedure remotely in an X-ray shielded control booth using low-strength magnetic fields,” says Choi. “It also does not require the high level of training needed for conducting conventional PCIs.”

More tests and improvements are still required, but the researchers are already planning to further modify their apparatus so it can also target vessels in the nervous system and lungs.

Latest Issues

EBME Expo 2026

Coventry Building Society Arena, Coventry
24th – 25th June 2026

AfPP Regional Conferences: Manchester

INNSiDE by Meliá Manchester
20th June 2026

Endoscopic Anterior Skull Base Surgery: Hands-On Cadaveric Course

Division of Anatomy, University of Leeds
29th- 30th June 2026

BLOCKED – Advanced+ | The Wrightington Regional Anaesthesia Interest Group Cadaveric Course

Wrightington Conference Centre
Tuesday 7th – Wednesday 8th July 2026

AESCULAP ACADEMY LIVE - Circular Economy in Action

B. Braun Business Centre, Sheffield
Friday 10th July 2026

AfPP Regional Conferences: Bristol

BAWA Leisure
18th July 2026